MS16625D
TABLE V. LIMIT LOADS.
NOMINAL RING SIZE |
ALLOWABLE THRUST LOAD FOR RING ASSEMBLIES WITH PARTS HAVING MAXIMUM CORNER RADII OR CHAMFERS. |
||
FROM |
TO |
TABLE I STEEL OR STAINLESS STEEL |
TABLE II BERYLLIUM COPPER |
.250 |
.312 |
190 LB |
.250 |
.375 |
.453 |
530 LB |
.375 |
.500 |
.750 |
1100 LB |
.500 |
.777 |
.938 |
1650 LB |
.777 |
1.000 |
1.500 |
2400 LB |
1.000 |
1.562 |
2.000 |
3900 LB |
1.562 |
2.062 |
2.531 |
2.052 |
2.052 |
2.652 |
3.000 |
3.062 |
3.062 |
3.062 |
5.000 |
5.250 |
5.250 |
5.250 |
6.000 |
6.250 |
6.250 |
6.250 |
7.000 |
7.250 |
7.250 |
7.250 |
10.000 |
7.250 |
7.250 |
NOTE: THE ABOVE FORMULAS ARE TO BE USED FOR BRITTLE MATERIALS SUCH AS CAST IRON, ETC.
WARNING: RINGS SHOULD NOT BE EXCESSIVELY CONTRACTED DURING INSTALLATION SINCE THIS WILL LEAD TO RING FAILURE. IF THE RING HAS PLAY BETWEEN THE GROOVE DIAMETER AND THE OUTSIDE RING DIAMETER THIS INDICATES THAT THE RING HAS BEEN EXCESSIVELY CONTRACTED, (PROVIDING
GROOVE DIAMETER HAS BEEN MACHINED TO RECOMMENDED DIMENSIONS).
4. CHANGES FROM PREVIOUS ISSUE. MARGINAL NOTATIONS ARE NOT USED IN THIS REVISION TO IDENTIFY CHANGES WITH RESPECT TO THE PREVIOUS ISSUE DUE TO THE EXTENT OF THE CHANGES.
MILITARY INTEREST
Custodians: Preparing activity: Army - AR DLA - IS
Navy - OS
Air Force - 99
Review activities: (Project 5325-2011-006) Army - AV, MI
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.