MS16626C
1 1
P = P CH P
= NEW ALLOWABLE THRUST LOAD
CH1 OR P = LISTED ALLOWABLE THRUST LOAD
1
WHERE: CH
= NEW (SMALLER) CHAMFER
CH = LISTED CHAMFER
1 1
P = PR R
1
= NEW (SMALLER) CORNER RADIUS
R R = LISTED CORNER RADIUS
LIMIT LOADS LISTED IN TABLE VI ARE BASED ON RINGS OF STEEL (WORKING STRESS = 250,000 PSI) AND OF BERYLLIUM COPPER (WORKING STRESS = 180,000 PSI). IF THE ALLOWABLE GROOVE CAPACITY LOADS, AS CALCULATED BY USING THE FORMULA ON PAGE 7 ARE LESS THEN THEY SHOULD BE USED.
TABLE VI. LIMIT LOADS.
NOMINAL RING SIZE |
ALLOWABLE THRUST LOAD FOR RING ASSEMBLIES WITH PARTS HAVING MAXIMUM CORNER RADII OR CHAMFERS. |
||
FROM |
TO |
CARBON STEEL OR CORROSION RESISTANT STEEL |
BERYLLIUM COPPER |
.500 .688 1.062 1.563 2.125 2.875 3.500 |
.672 1.000 1.500 2.000 2.500 3.156 3.938 |
680 LB 1000 LB 1460 LB 2250 LB 3750 LB 5550 LB 7850 LB |
500 LB 700 LB 1050 LB 1600 LB |
4. CHANGES FROM PREVIOUS ISSUE. MARGINAL NOTATIONS ARE NOT USED IN THIS REVISION TO IDENTIFY CHANGES WITH RESPECT TO THE PREVIOUS ISSUE DUE TO THE EXTENT OF THE CHANGES.
MILITARY INTEREST
Custodians: Preparing activity: Army - AR DLA - IS
Navy - OS
Air Force - 99 (Project 5325-2011-007)
Review activities:
Army - AT, AV, CR4, GL, MI Navy - MC
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.dla.mil.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business