MIL-DTL-22529D (AS)
4.2.7 High temperature and load deformation test. The grommets shall be
mounted in the test fixture as shown in Figure 2. The fixture with the
grommet, shall be placed in an ambient temperature for not less than 48 hours
per Table IV.
Table IV
+2°C
Grommet Type
80°
MIL-DTL-22529/2
100°
Nylon MS21266
120°
MIL-DTL-22529/1
250°
TFE MS21266
After returning to room temperature, the grommet area subjected to maximum
compression shall be cut to expose section "AA" of Figure 2. The grommet
dimensions shall conform to the requirements of 3.2.4.
4.2.8 Vibration test. The grommets shall be mounted in the test fixture
as shown in Figure 1, and subjected to the vibration test in accordance with
MIL-STD-202, Method 201A. The grommets shall conform to the requirements
specified in 3.2.5. Upon completion of the vibration test, the grommets shall
be subjected to and pass the dielectric strength test (see 4.2.9).
(SEE 6.3.1)
1"
1"
GROMMET ASSEMBLY
2
2
2
2
VOLTS
COPPER TUBE
(RMS)
OR
V
PER
ROD
GROMMET
TABLE V
1"
1
HOLE FOR MS21266
4
2" HOLE FOR MIL-DTL-22529/1A
ALUMINUM SHEET
AND MIL-DTL-22529/2
NOTE: METAL THICKNESS SHALL
CORRESPOND TO APPLICABLE
DASH NUMBER ON MS21266, MIL-DTL-22529/1A AND MIL-DTL-22529/2
FIGURE 1.
Dielectric strength test fixture.
4.2.9 Dielectric withstanding voltage test (dielectric strength). The
grommet shall be installed in the dielectric strength test fixture as
indicated in Figure 1 and tested in accordance with MIL-STD-202, Method 301.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business